Suche
 
Folgen Sie uns auf:

Nevada Copper Corp.: North Deposit Mineralization Remains Open Intersecting 119 Feet at 1.67% Copper

30.10.2012  |  Marketwired

VANCOUVER, BRITISH COLUMBIA -- (Marketwire) -- 10/30/12 -- Nevada Copper Corp. (TSX: NCU) ("Nevada Copper") is pleased to announce the remaining step-out and expansion drill results from its 100% owned Pumpkin Hollow Property located near Yerington, Nevada. The total drilling program consisted of ninety four (94) drill holes totaling 47,000 meters of which results totaling 44,000 meters were included in the recently released updated resource. As previously reported on September 7, 2012, the updated measured and indicated copper resource in the North, South, and Southeast deposits (the "Western Deposits") increased by over 1.1 billion pounds to 5.4 billion pounds.


The drill results reported below include the last three (3) holes drilled in the Western Deposits.


In the North deposit, drill hole NC12-36 continues to expand mineralization along the northwest edge. The hole targeted the expansion of the main mineralized zone down dip, intersecting 119.0 feet (36.3 meters), 84.1 feet (25.7 meters) true thickness, grading 1.67% copper, 0.288 g/t gold, and 5.7 g/t silver outside the current feasibility ultimate pit limit. Mineralization remains open to the north, down dip.


Drill hole NC12-35 was drilled in the northern part of the South deposit. Drill hole NC12-35 targeted deeper mineralization and intersected several zones, confirming the shallower zones and expanding the lower mineralized zone. The largest zone intersected, 490.0 feet (149.4 meters), 411.1 feet (125.3 meters) true thickness grading 0.27% copper.


Drill hole NC12-38 was drilled in the Southeast deposit to better define the copper mineralization in the deposit. The drilling confirmed and expanded the mineralization.


Gregory French, Vice President, Senior Project Manager, commented, "The assay results released today complete a very successful drill program that discovered new mineralization, re-classified mineral classes, and converted waste into mineralized material. Our recent drill program increased the measured and indicated copper resource in the Western Deposits by over 1.1 billion pounds to 5.4 billion pounds. The recent results from NC12-36 and the earlier reported NC12-34 which intersected 690 feet grading 1.17% copper demonstrate the further potential and open nature of the deposit. Whether it's down dip from NC12-36 or the large area around NC12-34, major areas remain open in the North Deposit. These holes are outside the current feasibility pit limits and were not included in the recent resource update. The newly discovered mineralization in the NC12-34 area will be a priority in future drilling."



NORTH DEPOSIT - Assays greater than 0.15% Cu

----------------------------------------------------------------------------
----------------------------------------------------------------------------
True
Drill Hole # From To Length Length Length Copper Gold Silver Mo
----------------------------------------------------------------------------
(m) (m) (m) (ft) (m) % (g/t) (g/t) (g/t)
----------------------------------------------------------------------------
----------------------------------------------------------------------------
NC12-36 258.6 265.2 6.6 21.5 4.7 0.21 0.010 0.6 0.002
----------------------------------------------------------------------------
289.3 296.6 7.3 24.0 5.2 0.45 0.013 1.5 0.009
----------------------------------------------------------------------------
367.6 382.8 15.2 50.0 10.7 0.30 0.040 1.6 0.005
----------------------------------------------------------------------------
393.2 422.2 29.0 95.0 20.5 0.31 0.036 1.5 0.009
----------------------------------------------------------------------------
428.2 434.3 6.1 20.0 4.3 0.27 0.031 1.3 0.008
----------------------------------------------------------------------------
463.3 499.6 36.3 119.0 25.7 1.67 0.288 5.7 0.003
----------------------------------------------------------------------------
507.5 514.5 7.0 23.0 4.9 0.27 0.066 2.0 0.003
----------------------------------------------------------------------------
521.2 536.4 15.2 50.0 10.7 0.29 0.075 1.9 0.004
----------------------------------------------------------------------------
550.2 556.3 6.1 20.0 4.3 0.91 0.033 3.1 0.005
----------------------------------------------------------------------------

SOUTH DEPOSIT - Assays greater than 0.15% Cu

----------------------------------------------------------------------------
----------------------------------------------------------------------------
True
Drill Hole # From To Length Length Length Copper Gold Silver Fe
----------------------------------------------------------------------------
(m) (m) (m) (ft) (m) % (g/t) (g/t) (%)
----------------------------------------------------------------------------
----------------------------------------------------------------------------
NC12-35 146.3 224.0 77.7 255.0 65.2 0.22 0.032 0.6 23.0
----------------------------------------------------------------------------
231.6 381.0 149.4 490.0 125.3 0.27 0.047 1.4 20.1
----------------------------------------------------------------------------
391.7 403.9 12.2 40.0 10.2 0.60 0.068 2.3 7.7
----------------------------------------------------------------------------
417.6 452.6 35.0 115.0 29.4 0.34 0.037 1.2 5.6
----------------------------------------------------------------------------
464.8 477.0 12.2 40.0 10.2 0.28 0.057 0.5 34.6
----------------------------------------------------------------------------
484.9 507.5 22.6 74.0 18.9 0.20 0.031 0.5 35.7
----------------------------------------------------------------------------

SOUTHEAST DEPOSIT - Assays greater than 0.15% Cu

----------------------------------------------------------------------------
----------------------------------------------------------------------------
True
Drill Hole # From To Length Length Length Copper Gold Silver Fe
----------------------------------------------------------------------------
(m) (m) (m) (ft) (m) % (g/t) (g/t) (%)
----------------------------------------------------------------------------
----------------------------------------------------------------------------
NC12-38 74.6 97.5 22.9 75.0 11.5 0.61 0.171 3.0 39.4
----------------------------------------------------------------------------
217.9 225.5 7.6 25.0 3.8 0.45 0.110 0.5 27.9
----------------------------------------------------------------------------


A cross section and plan maps with the respective drill hole locations are available at http://www.nevadacopper.com/i/pdf/121029nr-maps.pdf.


Follow Up Drill Program


A follow up drill program targeting the newly discovered mineralization of 690 feet (210.3 meters) grading 1.17% copper in drill hole NC12-34 is currently being planned. The mineralized zones are outside the current feasibility pit limits and were not included in the recent resource update reported on September 7, 2012. The drill results open up a very large prospective area where existing holes are shallow and the mineralized zones have not been drill tested. The nearest drill holes to the south and east are over 600 to 800 feet away.


Feasibility Study Update


Feasibility study work continues on schedule for a stand-alone high grade underground mine and mill as described in the News Release dated June 20, 2012. The production rate has been established at 6,500 tons per day, for an initial 12 year mine life. This feasibility study is well advanced with publication of results scheduled for release the week of November 19, 2012.


A separate, updated optimized feasibility study for an integrated open pit and underground operation ("Integrated Operation") which will incorporate the updated resource for the Western Deposits is scheduled for release by February 2013.


Shaft and Infrastructure Update


Work on the production-sized exploration shaft continues with a focus on surface facilities by Clark/Atkinson Construction. The foundation for the 12 foot double drum hoist is complete and arrangements are underway for installation and commissioning of the hoist. The concrete formwork for the sub-collar is in progress. Completion of the collar concrete is expected to coincide with delivery of the headframe steel in late November. Fabrication of the headframe structure by Utah Fabrication is approximately 32% complete and progressing well. Line power has now been established at the shaft construction site.


Permitting and Land Transfer Update


Nevada Copper continues to work toward receipt of State construction permits by the end of the first quarter of 2013. State Permit applications were submitted in July 2012 for both:



a. A Stand-Alone High Grade Underground Mine and mill located entirely on
private land; and,

b. Integrated Operation and single process facility.


The three key state permits are the Water Pollution Control Permit ("WPCP") for mining, a WPCP for dewatering and a Reclamation Permit. The Nevada Division of Environmental Protection, Bureau of Mining Regulation and Reclamation ("NDEP-BMMR") has deemed the two WPCP'S complete and is in technical review on those two permits.


Another key permit is a Nevada Air Quality Permit which can be attained in approximately sixty (60) days. Either a County or City Special Use Permit would be required, subject to the outcome of the proposed Yerington Land Conveyance and Sustainable Development Act (the "Yerington Bill") and will be submitted in January 2013 to assure approval in the first quarter of 2013.


Permit reviews are being done concurrently with Congressional action on the Yerington Bill. The Yerington Bill would transfer 10,400 acres Bureau of Land Management ("BLM") administered federal lands to the City of Yerington, 3,800 of which would be needed for the Integrated Operation. Subject to successful passage of the Yerington Bill the Integrated Operation alternative could be implemented with the granting of State Permits.


The City of Yerington, Lyon County and Nevada Copper are working together and with the Nevada Congressional delegation on a daily basis to assure passage of the Yerington Bill in the 112th Congress, which will reconvene after the U.S. elections on November 6 and close late in 2012. Senate Majority Leader Harry Reid of Nevada has said that he will be able to pass this legislation in the 112th Congress. Senator Reid, Senator Dean Heller and Congressman Mark Amodei continue to have the Yerington Bill as one of their top priorities in this Congress. The Yerington Bill is supported by the entire Nevada Congressional delegation, co-sponsored by Nevada Congresswoman Shelley Berkley and Nevada Congressman Joe Heck in the U.S. House of Representatives.


As a contingency, if the Yerington Bill were not to pass, open pit operations could be permitted as a second phase to the first phase stand-alone high grade underground mine and mill. A pre-application consultation was held with BLM in early October and a Plan of Operations will be submitted to BLM in November 2012 to initiate that review process. If the Yerington Bill is passed, that process would not be required and would be suspended.


Qualification Statement


The Pumpkin Hollow drilling program is under the supervision of Gregory French, CPG #10708, and a Qualified Person as defined in Canadian National Instrument 43-101, who is responsible for the preparation of the technical information in this news release. All assaying and whole rock geochemistry is processed at the American Assay Laboratories (AAL) in Reno, Nevada. Samples are delivered from the project core logging facility to AAL by Nevada Copper or AAL personnel. A Quality Assurance and Quality Control Assay Protocol have been implemented whereby blanks and standards are inserted into the assay stream and check samples are sent to Chemex-Reno and Inspectorate-Reno laboratories.


For additional information about Nevada Copper please visit our website at www.nevadacopper.com.


NEVADA COPPER CORP.


Giulio T. Bonifacio, President & CEO


We seek safe habor.

Contacts:

Nevada Copper Corp.

Eugene Toffolo

VP, Investor Relations & Communications

604-683-8266 or Toll free: 1-877-648-8266
etoffolo@nevadacopper.com


Nevada Copper Corp.

Robert McKnight, P.Eng.

Executive Vice President & CFO

604-683-1309
bmcknight@nevadacopper.com
www.nevadacopper.com


Bewerten 
A A A
PDF Versenden Drucken

Für den Inhalt des Beitrages ist allein der Autor verantwortlich bzw. die aufgeführte Quelle. Bild- oder Filmrechte liegen beim Autor/Quelle bzw. bei der vom ihm benannten Quelle. Bei Übersetzungen können Fehler nicht ausgeschlossen werden. Der vertretene Standpunkt eines Autors spiegelt generell nicht die Meinung des Webseiten-Betreibers wieder. Mittels der Veröffentlichung will dieser lediglich ein pluralistisches Meinungsbild darstellen. Direkte oder indirekte Aussagen in einem Beitrag stellen keinerlei Aufforderung zum Kauf-/Verkauf von Wertpapieren dar. Wir wehren uns gegen jede Form von Hass, Diskriminierung und Verletzung der Menschenwürde. Beachten Sie bitte auch unsere AGB/Disclaimer!




Mineninfo
Nevada Copper Corp.
Bergbau
-
-
Minenprofile
Alle Angaben ohne Gewähr! Copyright © by GoldSeiten.de 1999-2024.
Die Reproduktion, Modifikation oder Verwendung der Inhalte ganz oder teilweise ohne schriftliche Genehmigung ist untersagt!

"Wir weisen Sie ausdrücklich auf unser virtuelles Hausrecht hin!"